horlogo2.gif (5076 bytes)
  Herringbone

vert_logo4.gif (5669 bytes)
vert_logo4.gif (5669 bytes)
her_config.gif (9383 bytes)
     The Ambi-Rad Herringbone system combines the even heat distribution of the continuous tube system with the economy of a unitary heater system to deliver a most effective system at a more competitive price. The Herringbone system is comprised of up to ten individual radiant heaters connected by a common vacuum pump. This manifold system eliminates multiple roof penetrations by discharging through the common vacuum pump.
       Each radiant heater incorporates highly reflective steel reflectors which are mounted in such a way as to permit free thermal expansion, and are easily detachable for cleaning, or whenever access is required. The gas burner fires into one end of the emitter tube and at the exit end is a damper assembly, used to balance the system at start-up. The emitter tubes are heated by the passage of hot combustion gases and the hot tubes emit infra-red radiant heat, which is directed downwards by the reflector towards the occupied workspace.
  herring.gif (20667 bytes)
 

Features

  • Common exhaust eliminates multiple roof penetrations
  • Vacuum fan principal, induced burner combustion
  • Burner ratings of 40,000 Btu/h to 150,000 Btu/h
  • Highly polished aluminum/stainless steel reflectors for long life and maximum radiant efficiency
  • Vacuum proving switch to prevent activation on loss of vacuum
  • Combustion chamber isolated from control compartment to prevent combustion air from being drawn across the controls
  • Direct spark ignition
  • Power and burner on indicator lights
  • Flame inspection sight glass
  • Durable brackets with bolted reflectors
  • Natural or propane gas
  • Cast iron burner head
  • AGA Certified
 

Benefits

  • Minimum flue penetration
  • Zone control flexibility
  • Mix U-tube and straight tube heaters
  • Quieter operation

Straight Tube U-Tube
Model Input 1000 Btu/h Tube Length (ft.) Model Input 1000 Btu/h Tube Length (ft.)
ER 12/15/18/22-S20 40/50/60/75 20 ER 12-U20/U30 40 20/30
ER 12/15/18/22-S25 40/50/60/75 25 ER 15-U20/U30 50 20/30
ER 12/15/18/22-S30 40/50/60/75 30 ER 18-U20/U30 60 20/30
ER 18/22-S40 60/75 40 ER 12-U20/U30 75 20/30
ER 29/38/44-S40 100/130/150 40 ER 29-U35 100 35
ER 29/38/44-S50 100/130/150 50 ER 38-U35 130 35
ER 12/29/38/44-S60 100/130/150 60 ER 44-U35 150 35
 
Electrical 120 V 60 HZ
Running Current 1.2 A
Gas Supply Pressure Natural 6.5 w.g. min. 14.0 w.g. max.
LP. 11.0 w.g. min. 16.0 w.g. max.

 

 

 

 

 

 

 

 



Ambi-Rad

12910 Ford Dr
Fishers, IN 46038
1-888-330-4878